Adjusting Shift Lock Solenoid(with automatic shift lock only) The operation of the shift lock is shown in Fig. 4-10. The shift lock is engaged when the relay actuates the shift lock solenoid. The solenoid moves the shift lock plate to lock the selector lever pushrod in place. This prevents moving the selector lever from its selected position. The shift lock solenoid is mounted in slotted holes and its position is adjustable. Disconnect the harness connector and adjust when the solenoid is not actuated. Loosen the solenoid mounting screws and position the solenoid as necessary. The correct adjustment is illustrated in Fig. 4-11. Following the adjustment, check operation of the shift lock in Park and Neutral, and operation of the selector lever in all positions.
|
|
|